Extensively Tested by Independent Testing Laboratories

VISIONWALL products are tested by respected independent testing laboratories to substantiate their thermal, acoustical and structural performance. Please contact marketing@visionwall.com for a copy of these test reports.

4-Element: Fixed Window
4-Element: Casement Window

4 Element Curtain Wall


3-Element: Fixed Window

3-Element: Casement Window

3-Element: Outswing Awning Window

3-Element: Outswing Casement Window 


4 Element
Window or Curtain Wall (Our Series #)
Results
Standard
Thermal/
Condens. Resist. (CRF),
Structural or Acoustic
Tested By:
Fixed Window 
(Series 100)
•   Thermal Resistance
     R = 1.07 m2 ºK/W (6.08 hr ft2 ºF/Btu)
•  Condensation Resistance
     If = 82%, Ig = 73%
CAN/CSA Thermal/CRF National Research Council
Report #CR6280.1
Fixed Window
(Series 100)
•   Temperature Index: I=73.2 CAN/CSA Thermal/CRF Architectural Testing Inc.
Report #ATI-8743
Fixed Window
(Series 100) 
•   Air Tightness: Passed
       0.063 m3/hr/m (0.01 cfm/ft) of crack length
•  Water Tightness: B7 Rating
•  No leakage @ 700 Pa (14.61psf) pressure
•  Blowout: C5 Rating
•  No breakage or damage @ 5.0 kPa (104 psf)
CAN/CSA Structural Warnock Hersey
Report #50281-C7-1295-1
Fixed Window
(Series 100) 
•   Thermal Transmission: U-Class U20
     U = 0.15 Btu/hr ft2 ºF (0.85 W/m2 ºK)
•  Condensation Resistance:
     CRF Class C65,
     CRFf = 89, CRFg = 87
•  Air Infiltration
     <0.01 cfm/ft2 @ 0.112" H2O (15 mph)
    0.01 cfm/ft2 @ 0.300" H2O (25 mph)
AAMA Thermal/CRF Architectural Testing Inc.
Report #ATI-8735
Fixed Window
(Series 100) 
•   Sound Transmission Class: STC=42 AAMA Acoustical University of Alberta
Report #90-19
Fixed Window
(Series 200)
•   Air Infiltration: Passed
     0.078 m3/hr/m of crack length 
     (0.014 cfm/ft of crack length)
•  Water Penetration: B7 Rating
•  No leakage @ 700 Pa (14.7 psf)
•  Blowout: C5 Rating
•  Deflection: C5 Rating
CAN/CSA Structural AGRA Earth & Environmental
Report #CA-105002.25
Fixed Window
(Series 200) 
Air Infiltration
     0.442 m3/hr/m2 @ 300 Pa
     (0.024 cfm/ft2 @ 6.30 psf)
•  Water Penetration
       No leakage @ 700 Pa (14.7 psf)
•  Uniform Load Deflection
     L/1050 @ 3330 Pa (69.9 psf)
AAMA Structural AGRA Earth & Environmental
Report #CA-105002.26
Fixed Window
(Series 200) 
•   Sound Transmission Class: STC= 38 to 45 AAMA Acoustical University of Alberta
Report #93-04
Casement Window
Series 100) 
•   Temperature Index: I=73.6 CAN/CSA Thermal/CRF Architectural Testing Inc.
Report #ATI-8744
Casement Window
(Series 100) 
•   Air Tightness: A3 Rating 0.058 m3/hr/m 
     (0.01 cfm/ft) of crack length 
•  Water Tightness: B7 Rating
•  No leakage @ 700 Pa (14.6 psf) pressure
•  Deflection: Passed
     <1/2000th of span @ 2.0 kPa (41.8 psf)
•  Blowout: C5 Rating
•  Ease of Operation: Passed
Sash Strength and Stiffness: Passed
CAN/CSA Structural Warnock Hersey
Report #50281-C7-1296-1R
Casement Window
(Series 100)
Thermal Transmission: U-Class U20
        U = 0.16 Btu/hr ft2 ºF (0.91 W/m2 ºK)
Condensation Resistance:
        CRF Class C65, 
        CRFf = 88, CRFg = 87
Air Infiltration
        0.01 cfm/ft2 @ 0.112" H2O (15 mph)
        0.02 cfm/ft2 @ 0.300" H2O (25 mph)
AAMA Thermal/CRF Architectural Testing Inc.
Report #ATI-8736
Curtain Wall
(Series 300) 
•   Static Air Infiltration: Passed
     0.014 cfm/ft2 @ 6.24 psf
•  Static Water Infiltration: Passed 
     No leakage @ 10.00 psf
•  Dynamic Water Infiltration: Passed
       No leakage @ 10.00 psf
•  Structural Design Load: Passed 
      Within L/175 of span @ +/- 25 psf
•  Structural Proof Load: Passed
     Tested @ +/- 37.5 psf
AAMA Structural Mid America Testing Lab Inc
Report #M-36-92

3-Element
top
Window or Curtain Wall (Our Series #)
Results
Standard
Thermal/
Condens. Resist.(CRF),
Structural or Acoustic
Tested By:
Fixed Window
(Series M20)
•   Air Infiltration: Passed
     0.044 m3/hr/m of crack length 
     (0.008 cfm/ft of crack length)
•  Water Penetration: B7 Rating
     No leakage @ 700 Pa (14.7 psf)
•  Blowout: C4 Rating
•  Deflection: C4 Rating
CAN/CSA Structural AGRA Earth & Environmental
Report #CA105002.61
Fixed Window
(Series M20)
•   Thermal Transmission:
     U = 0.22 Btu/hr ft2 ºF
•   Condensation Resistance:
     CRF Class C70
     CRFf = 73
     CRFg = 80
•  Air Infiltration
     <0.01 cfm/ft2 @ 0.57 psf
     <0.01 cfm/ft2 @ 1.57 psf
AAMA Thermal/CRF Quality Testing Inc.
Report #T96-059
Fixed Window
(Series M20)
•   Air Infiltration:
     0.321 m3/hr/m2 @ 300 Pa
     (0.017 cfm/ft2 @ 6.30 psf)
•  Water Penetration
     No leakage @700 Pa (14.7 psf)
•  Uniform Load Deflection:
     L/189 @ 3330 Pa (69.9 psf)
AAMA Structural AGRA Earth & Environmental
Report #CA105002.61A
Fixed Window
(Series M20)
•   Sound Transmission Class: STC = 36 to 44 AAMA Accoustical University of Alberta
Report #96-01
Casement Window
(Series M20)
•   Air Infiltration: Passed
     0.118 m3/hr/m of crack length 
     (0.002 cfm/ft of crack length)
•  Water Penetration: B7 Rating
     No leakage @ 700 Pa (14.7 psf)
•  Blowout: C5 Rating
•  Deflection: C5 Rating
•  Ease of Operation: Passed
•  Sash Strength and Stiffness: Passed
CAN/CSA Structural AGRA Earth & Environmental
Report #CA-105002.62
Casement Window
(Series M20)
•   Thermal Transmission:
     U = 0.30 Btu/hr ft2 ºF
•  Condensation Resistance:
     CRF Class C70
     CRFf = 72
     CRFg = 79
•  Air Infiltration
     <0.01 cfm/ft2 @ 0.57 psf
     <0.01 cfm/ft2 @ 1.57 psf
AAMA Thermal/CRF Quality Testing Inc.
Report #T96-060
Casement Window
(Series M20)
•   Air Infiltration
     1.295 m3/hr/m2 @ 300 Pa
     (0.071 cfm/ft2 @ 6.30 psf)
•  Water Penetration
    No leakage @ 700 Pa (14.7 psf)
AAMA Structural AGRA Earth & Environmental
Report #CA-105002.62A
Outswing Awning Window
(Series M20)
•   Air Infiltration: Passed
      0.078 m3/hr/m of crack length 
      (0.014 cfm/ft of crack length)
•  Water Penetration: B7 Rating
     No leakage @ 700 Pa (14.7 psf)
•  Blowout: C5 Rating
•  Deflection: C5 Rating
•  Ease of Operation: Passed
•  Sash Strength and Stiffness: Passed
•  Resistance to Forced Entry: F2 Rating
CAN/CSA Structural AGRA Earth & Environmental
Report #CA-15002.95
Outswing Awning Window
(Series M20)
•   Air Infiltration:
     0.215 m3/hr/m @300 Pa
     (0.039 cfm/ft @ 6.30 psf)
•  Water Penetration:
     No leakage @ 700 Pa (14.7 psf)
AAMA Structural AGRA Earth & Environmental
Report #CA-15002.95A
Outswing Casement Window
(Series M20)
•   Air Infiltration: Passed
     0.213 m3/hr/m of crack length 
     0.038 cfm/ft of crack length)
•  Water Penetration: B7 Rating
     No leakage @ 700 Pa (14.7 psf)
•  Blowout: C5 Rating
•  Deflection: C5 Rating
•  Ease of Operation: Passed
•  Sash Strength and Stiffness: Passed
•  Resistance to Forced Entry: F2 Rating
CAN/CSA Structural AGRA Earth & Environmental
Report #CA-15002.96
Outswing Casement Window
(Series M20)
•   Air Infiltration:
     0.442 m3/hr/m @ 300 Pa
     (0.080 cfm/ft @ 6.30 psf)
•  Water Penetration:
     No leakage @ 700 Pa (14.7 psf)
AAMA Structural AGRA Earth & Environmental
Report #CA-15002.96A