4
Element |
|
|
|
|
|
Window or Curtain
Wall (Our Series #)
|
Results
|
Standard
|
Thermal/
Condens.
Resist. (CRF),
Structural
or Acoustic
|
Tested By:
|
Fixed
Window
(Series
100) |
•
Thermal Resistance
R = 1.07 m2 ºK/W (6.08 hr ft2 ºF/Btu)
•
Condensation Resistance
If = 82%, Ig = 73% |
CAN/CSA |
Thermal/CRF |
National
Research Council
Report
#CR6280.1 |
Fixed
Window
(Series
100) |
•
Temperature Index: I=73.2 |
CAN/CSA |
Thermal/CRF |
Architectural
Testing Inc.
Report
#ATI-8743 |
Fixed
Window
(Series
100) |
•
Air Tightness: Passed
0.063 m3/hr/m (0.01
cfm/ft) of crack length
•
Water Tightness: B7 Rating
•
No leakage @ 700 Pa (14.61psf) pressure
•
Blowout: C5 Rating
•
No breakage or damage @ 5.0 kPa (104 psf) |
CAN/CSA |
Structural |
Warnock
Hersey
Report
#50281-C7-1295-1 |
Fixed
Window
(Series
100) |
•
Thermal Transmission: U-Class U20
U = 0.15 Btu/hr ft2 ºF (0.85 W/m2 ºK)
•
Condensation Resistance:
CRF Class C65,
CRFf = 89, CRFg = 87
•
Air Infiltration
<0.01 cfm/ft2 @ 0.112" H2O (15 mph)
0.01 cfm/ft2 @ 0.300" H2O (25 mph) |
AAMA |
Thermal/CRF |
Architectural
Testing Inc.
Report
#ATI-8735 |
Fixed
Window
(Series
100) |
•
Sound Transmission Class: STC=42 |
AAMA |
Acoustical |
University
of Alberta
Report
#90-19 |
Fixed
Window
(Series
200) |
•
Air Infiltration: Passed
0.078 m3/hr/m of crack length
(0.014 cfm/ft of crack length)
•
Water Penetration: B7 Rating
•
No leakage @ 700 Pa (14.7 psf)
•
Blowout: C5 Rating
•
Deflection: C5 Rating |
CAN/CSA |
Structural |
AGRA
Earth & Environmental
Report
#CA-105002.25 |
Fixed
Window
(Series
200) |
•
Air Infiltration
0.442 m3/hr/m2 @ 300 Pa
(0.024 cfm/ft2 @ 6.30 psf)
•
Water Penetration:
No leakage @ 700 Pa (14.7 psf)
•
Uniform Load Deflection
L/1050 @ 3330 Pa (69.9 psf) |
AAMA |
Structural |
AGRA
Earth & Environmental
Report
#CA-105002.26 |
Fixed
Window
(Series
200) |
•
Sound Transmission Class: STC= 38 to 45 |
AAMA |
Acoustical |
University
of Alberta
Report
#93-04 |
Casement
Window
Series
100) |
•
Temperature Index: I=73.6 |
CAN/CSA |
Thermal/CRF |
Architectural
Testing Inc.
Report
#ATI-8744 |
Casement
Window
(Series
100) |
•
Air Tightness: A3 Rating 0.058 m3/hr/m
(0.01 cfm/ft) of crack length
•
Water Tightness: B7 Rating
•
No leakage @ 700 Pa (14.6 psf) pressure
•
Deflection: Passed
<1/2000th of span @ 2.0 kPa (41.8 psf)
•
Blowout: C5 Rating
•
Ease of Operation: Passed
• Sash
Strength and Stiffness: Passed |
CAN/CSA |
Structural |
Warnock
Hersey
Report
#50281-C7-1296-1R |
Casement
Window
(Series
100) |
•
Thermal Transmission: U-Class U20
U = 0.16 Btu/hr ft2 ºF (0.91 W/m2 ºK)
• Condensation
Resistance:
CRF Class C65,
CRFf = 88, CRFg = 87
• Air
Infiltration
0.01 cfm/ft2 @ 0.112" H2O (15 mph)
0.02 cfm/ft2 @ 0.300" H2O (25 mph) |
AAMA |
Thermal/CRF |
Architectural
Testing Inc.
Report
#ATI-8736 |
Curtain
Wall
(Series
300) |
•
Static Air Infiltration: Passed
0.014 cfm/ft2 @ 6.24 psf
•
Static Water Infiltration: Passed
No
leakage @ 10.00 psf
•
Dynamic Water Infiltration: Passed
No leakage @ 10.00 psf
•
Structural Design Load: Passed
Within L/175 of span @ +/- 25 psf
•
Structural Proof Load: Passed
Tested
@ +/- 37.5 psf |
AAMA |
Structural |
Mid
America Testing Lab Inc
Report
#M-36-92 |
3-Element |
top |
|
|
|
|
Window or Curtain
Wall (Our Series #)
|
Results
|
Standard
|
Thermal/
Condens.
Resist.(CRF),
Structural
or Acoustic
|
Tested By:
|
Fixed
Window
(Series
M20) |
•
Air Infiltration: Passed
0.044 m3/hr/m of crack length
(0.008 cfm/ft of crack length)
•
Water Penetration: B7 Rating
No
leakage @ 700 Pa (14.7 psf)
•
Blowout: C4 Rating
•
Deflection: C4 Rating |
CAN/CSA |
Structural |
AGRA
Earth & Environmental
Report
#CA105002.61 |
Fixed
Window
(Series
M20) |
•
Thermal Transmission:
U = 0.22 Btu/hr ft2 ºF
•
Condensation Resistance:
CRF Class C70
CRFf = 73
CRFg = 80
•
Air Infiltration:
<0.01 cfm/ft2 @ 0.57 psf
<0.01 cfm/ft2 @ 1.57 psf |
AAMA |
Thermal/CRF |
Quality
Testing Inc.
Report
#T96-059 |
Fixed
Window
(Series
M20) |
•
Air Infiltration:
0.321 m3/hr/m2 @ 300 Pa
(0.017 cfm/ft2 @ 6.30 psf)
•
Water Penetration:
No
leakage @700 Pa (14.7 psf)
•
Uniform Load Deflection:
L/189 @ 3330 Pa (69.9 psf) |
AAMA |
Structural |
AGRA
Earth & Environmental
Report
#CA105002.61A |
Fixed
Window
(Series
M20) |
•
Sound Transmission Class: STC
= 36 to 44 |
AAMA |
Accoustical |
University
of Alberta
Report
#96-01 |
Casement
Window
(Series
M20) |
•
Air Infiltration: Passed
0.118 m3/hr/m of crack length
(0.002 cfm/ft of crack length)
•
Water Penetration: B7 Rating
No
leakage @ 700 Pa (14.7 psf)
•
Blowout: C5 Rating
•
Deflection: C5 Rating
•
Ease of Operation: Passed
•
Sash Strength and Stiffness: Passed |
CAN/CSA |
Structural |
AGRA
Earth & Environmental
Report
#CA-105002.62 |
Casement
Window
(Series
M20) |
•
Thermal Transmission:
U = 0.30 Btu/hr ft2 ºF
•
Condensation Resistance:
CRF Class C70
CRFf = 72
CRFg = 79
•
Air Infiltration
<0.01 cfm/ft2 @ 0.57 psf
<0.01 cfm/ft2 @ 1.57 psf |
AAMA |
Thermal/CRF |
Quality
Testing Inc.
Report
#T96-060 |
Casement
Window
(Series
M20) |
•
Air Infiltration:
1.295 m3/hr/m2 @ 300 Pa
(0.071 cfm/ft2 @ 6.30 psf)
•
Water Penetration:
No
leakage @ 700 Pa (14.7 psf) |
AAMA |
Structural |
AGRA
Earth & Environmental
Report
#CA-105002.62A |
Outswing
Awning Window
(Series
M20) |
•
Air Infiltration: Passed
0.078 m3/hr/m of crack length
(0.014 cfm/ft of crack length)
•
Water Penetration: B7 Rating
No
leakage @ 700 Pa (14.7 psf)
•
Blowout: C5 Rating
•
Deflection: C5 Rating
•
Ease of Operation: Passed
•
Sash Strength and Stiffness: Passed
•
Resistance to Forced Entry: F2 Rating |
CAN/CSA |
Structural |
AGRA
Earth & Environmental
Report
#CA-15002.95 |
Outswing
Awning Window
(Series
M20) |
•
Air Infiltration:
0.215 m3/hr/m @300 Pa
(0.039 cfm/ft @ 6.30 psf)
•
Water Penetration:
No
leakage @ 700 Pa (14.7 psf) |
AAMA |
Structural |
AGRA
Earth & Environmental
Report
#CA-15002.95A |
Outswing
Casement Window
(Series
M20) |
•
Air Infiltration: Passed
0.213 m3/hr/m of crack length
0.038 cfm/ft of crack length)
•
Water Penetration: B7 Rating
No
leakage @ 700 Pa (14.7 psf)
•
Blowout: C5 Rating
•
Deflection: C5 Rating
•
Ease of Operation: Passed
•
Sash Strength and Stiffness: Passed
•
Resistance to Forced Entry: F2 Rating |
CAN/CSA |
Structural |
AGRA
Earth & Environmental
Report
#CA-15002.96 |
Outswing
Casement Window
(Series
M20) |
•
Air Infiltration:
0.442 m3/hr/m @ 300 Pa
(0.080 cfm/ft @ 6.30 psf)
•
Water Penetration:
No leakage @ 700 Pa (14.7 psf) |
AAMA |
Structural |
AGRA
Earth & Environmental
Report
#CA-15002.96A |