Interior Glazed Curtain Wall VISIONWALL interior glazed curtain wall is available in either the 3 or 4-element glazing arrangements. The performance ranges used to choose one or the other are: |
|||
|
3-Element
|
4-Element
|
||||
| Winter Design Temperature of: | Above
0°F Above -18°C |
Below
0°F Below -18°C |
|||
| *R-Value of: | 2.7 to 4.7 | 4.0 to 7.1 | |||
| *U-Value of: | 0.37 to 0.21 Btu/hr•ft2•°F | 0.25 to 0.14 Btu/hr•ft2•°F | |||
| *U-Value of: | 2.10 to 1.21 W/m2•°C | 1.39 to 0.81 W/m2•°C | |||
| Sound Transmission Class of: |