VISIONWALL windows are available in either the 3 or 4-element glazing arrangements. The performance ranges to used choose one or the other are: |
|||
|
3-Element
|
4-Element
with
bold sightlines |
4-Element
with narrower sightlines |
|||
| Winter Design Temperature of: | Above
0°F Above -18°C |
Below
0°F Below -18°C |
Below
0°F Below -18°C |
||
| *R-Value of: | 2.7 to 4.7 | 4.0 to 7.1 | 4.0 to 7.1 | ||
| *U-Value of: | 0.37 to 0.21 Btu/hr•ft2•°F | 0.25 to 0.14 Btu/hr•ft2•°F | 0.25 to 0.14 Btu/hr•ft2•°F | ||
| *U-Value of: | 2.10 to 1.21 W/m2•°C | 1.39 to 0.81 W/m2•°C | 1.39 to 0.81 W/m2•°C | ||
| Sound Transmission Class of: |
36
to 44
|
40
to 45
|
40 to 45 | ||
| * R & U values shown above are for the complete window (glazing unit & frame) and take into the account the impact of edge conditions and frame construction on the window's performance. | |||||